الفهرس | Only 14 pages are availabe for public view |
Abstract Conclusion The PPS designed and described in the present study seems to be reliable for monitoring and controlling the NMs , RSs and the R&D facility The application of passive gamma-ray Non-Destructive Assay Technique using a scintillation spectrometer system gives acceptable results for identifying any of NMs or RSs transferred from or to the nuclear facility. |