Comparison of post LASIK IOL power calculation using post LASIK formulae versus 3rd &4th generation formulae with equivalent refractive power /
الناشر
Ashgan Mohammed Asaad Tawfik ,
المؤلف
Ashgan Mohammed Asaad Tawfik
هيئة الاعداد
باحث / Ashgan Mohammed Asaad Tawfik
مشرف / Zeinab Elsanabary
مشرف / Cherine Osman
مشرف / Samah Elbahrawy
تاريخ النشر
2016
عدد الصفحات
106 P. :
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
طب العيون
تاريخ الإجازة
9/3/2016
مكان الإجازة
جامعة القاهرة - كلية الطب - Ophthalmology
الفهرس
Only 14 pages are availabe for public view

from 115

from 115

Abstract

The aim of this study is to evaluate the available methods for IOL power calculation after LASIK surgery. Methodology:The study was conducted on 61 eyes that had undergone LASIK surgery previously. Two methods were used for IOL power calculation, the first was done by measurement of equivalent refractive power of the cornea by pentacam and feeding it into 3rd & 4th generation formulae (SRK-T, Hoffer-Q &Haigis), and the second was done by IOL master calculating IOL power by post LASIK formulae (Haigis-L &Shammas-PL) and comparison was done between the two methods.Results: In myopia: A significant difference was found between formulae used with equivalent refractive power of the cornea and post LASIK formulae with automated keratometry, but there is no significant difference between SRK-T formula with equivalent refractive power and Shammas-PL formula. In hypermetropia: there is no significant difference between formulae used with equivalent refractive power of the cornea and post LASIK formulae with automated keratometry.Conclusion: Both methods may be used for IOL power calculation after LASIK but need to be studied more pre and postoperatively to evaluate the postoperative refraction