Search In this Thesis
   Search In this Thesis  
العنوان
Stress analysis of two different attachments for a single implant retained mandibular overdentures in the midline :
الناشر
Ahmed Hasanin Mohammed Rashad ,
المؤلف
Ahmed Hasanin Mohammed Rashad
هيئة الاعداد
باحث / Ahmed Hasanin Mohammed Rashad
مشرف / Hamdy Abou Elfotouh Hamed
مشرف / Nouran Mahmoud Abdel Nabi
مناقش / Eatimad Alrekabi Taha
مناقش / Noura Mohammed Cheta
تاريخ النشر
2020
عدد الصفحات
81 P. :
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
Dentistry (miscellaneous)
تاريخ الإجازة
7/2/2020
مكان الإجازة
جامعة القاهرة - كلية الهندسة - Oral Implantology
الفهرس
Only 14 pages are availabe for public view

from 82

from 82

Abstract

Aim: The aim of this in vitro study is to record the induced micro-strain around one installed implant in the midline of a completely edentulous mandible using strain gauges utilizing an implant retained overdenture with two different types of attachments Ball and CMLOC attachment. Methodology : An acrylic resin test resin test model representing a completely edentulous lower arch was used The distal part of the residual ridge was covered with silicon based soft liner to stimulate the mucopcriostcum. Steps of complete denture fabrication was followed in conventional manner .Duplication of the finished denture was carried out to be used as a surgical stent .A single implant installed in the midline.After the implant was installed in the acrylic resin cast, the ball attachment was screwed to the implant.The denture was prepared for the direct pick up procedure, the same procedure repeated for CM IOC attachment. Four strain gauges around were installed on all surfaces of implant (Buccal. Lingual. Mesial .Distal) to monitor the effect of the applied loads vertical on the two types of attachments. A vertically load applied of 100 N static load was applied by using universal testing machine at three different sites (unilateral right first molar central fossa, left first molar and bilaterally. Results: When the load applied on the right side and left side ,it was shown that the single implant retained ovcrdenture with ball the attachment has shown higher microstrain than the CMLOC ,average microstrain for CMLOC ( 222.23) N ,and for Ball (394.64) N for right side, for left side average, microstrain for Ball (391.26) N , and for CMLOC (223.22) N . When the load applied bilaterally, the single implant retained ovcrdenturc with the CMLOC (269.05)N attachment has shown higher microstrain than the Ball (106.79)